PIPE
TYPES
These
test criteria are for fittings connecting to
the following Polyethylene pipes:
TEST
CRITERIA
Hydrostatic
Pressure Test:
Standard: None Available
Principle: Checking the leakproofness of joints of an assembly.
Test Temperature: 20 ± 2 °C
Test Pressures and Duration: 3.2 x Working Pressure of
Pipe for 1 minute
2.5
x Working Pressure of Pipe for 1 hour
2.1
x Working Pressure of Pipe for 1000 hours
Note
that the Hydrostatic Pressure Test of Fittings
in CSA Standard B137.0-99, clause 6.6.6 are exceeded
by the above Hydrostatic Pressure Test
Pull-out
Test:
Standard: ISO 3501-1976
Principle: Checking of the ability of an assembled joint to resist
pulling out when subjected to longitudinal tension.
Test Temperature: 20 ± 2 °C
Test
force: As per formula in ISO 3501 – 1976
Test
duration: 1 hour
Certification:
Certification
has been granted as follows:
TOXICITY: NSF 61 for Potable water
PERFORMANCE: |